Views:0 Author:Site Editor Publish Time: 2018-12-24 Origin:Site Inquire
Fault phenomenon 10:One end of the cross wire of the welded wire mesh machine cannot be properly pulled onto the positioning magnet
Causes and elimination of the fault:
1.The straightness of the cross thread does not meet the requirements.It is necessary to adjust the straightening angle of the straightening machine to ensure that the straightness error of the weft wire is within the standard range.
2.The force on both sides of the cross wire is uneven,and the silk is adjusted.The length of the weft extension is basically the same on both sides of the wheel;
3.The two parallel grooves of the cross wire form an angle between the parallel line and the parallel line of the cross material, and the front and rear positions of the cross wire wheel need to be adjusted to ensure two or The three winding wheel grooves are parallel on one line;
4.One end of the cross is bent or horseshoe-shaped or burred,and the gap of the steel straightening machine needs to be adjusted or the cutter is replaced.