Views:0 Author:Site Editor Publish Time: 2018-11-29 Origin:Site Inquire
Concrete use environment requirements for galvanized building mesh welding machine
1. Ambient temperature: 5 ~ 40 ° C
2. Relative humidity of air: maximum 90 at 20 °C and maximum 50 at 40 °C.
3. The altitude should be less than 2000 meters.
4. The machine is away from the equipment with large vibration.
5. The dust, acid, corrosive gas or substance in the air around the galvanized building mesh welding machine does not exceed the normal content.
6. It can't be used in the open air. It must be used in the factory building where the person is on duty at the factory gate.
7. Keep away from strong magnetic fields.
8. Power: AC 380V50HZ is recommended to use a separate 250-600KVA transformer, 180mm square copper wire for distance ≤50m cable. .
9. Water: Provide clean and neutral circulating cooling water, the inlet water temperature is not more than 40 °C in summer (refer to the cooling pool volume is not less than 2 cubic meters), 0.2 ≤ pressure ≤ 0.3MPa
10. Gas: Provide screw air compressor with pressure ≥0.8MPa, gas production ≥3.4m3/min and gas storage tank with pressure ≥0.8MPa and capacity ≥2m3/min. It is recommended to use the cold dryer with it.
11.Galvanized building mesh welding machine 3-6mm steel straightening and cutting machine and cold-rolled ribbed equipment.